Delivered Outcome · v1.1.0 · Civil / MEP Takeoff

Construction Plans Material Takeoff

Supplier-ready material schedules and RFQ spreadsheets extracted from three approved plan sets: GSW domestic water (Cypress), City of Whittier public water (Franklin St), and LA County Tract 82457 sewer (Whittier area). v1.1 reconciles all requestor feedback — 100% quantity resolution.

DELIVERED 100% quantities 3 plan sets 79 line items

Plan sets

SET A — GSW Cypress

5732 Lincoln Ave · 20 townhomes · Domestic water · 34 line items · 530.22 LF 8" PVC main

SET B — Whittier Water

13410 Franklin St · WT 23-025 · 21 line items · 33 LF 4" DIP + 25 LF 6" DIP (Sheet 2 table)

SET C — Tract 82457 Sewer

PC 12447 · Willows Court / Richvale · 24 line items · 684.44 LF 8" VCP (data table — corrected from profile sum)

Delivery package contents

materials-schedule.xlsx

Master procurement schedule by plan set. Filter-enabled worksheets.

supplier-rfq.xlsx

RFQ-ready lines with vendor pricing columns. Send filtered tabs directly to suppliers.

missing-information-register.xlsx

4 advisory field-verify items (Status = Advisory). Zero blocking quantity gaps.

assumptions-register.xlsx

Assumptions applied during takeoff (stationing, scaling, trench models).

quantity-completion-report.xlsx

100% internal quantity resolution — 23/23 originally flagged items resolved in v1.1.

REQUESTOR-FEEDBACK-REPORT.md

Root-cause analysis plus v1.1 reconciliation pass documenting all fixes.

v1.1 reconciliation — requestor feedback resolved

v1.1.0 update: All requestor observations addressed. Zero QUANTITY_REQUIRED line items remain.

1. Whittier 4" and 6" pipe — confirmed and relabeled

Still 33 LF 4" DIP + 25 LF 6" DIP from Sheet 2 Items 1–2. Rows now explicitly named NEW 4" / NEW 6" CL 350 C104 DIP Water Pipe. MJ tees corrected to 12"x12"x4" and 12"x12"x6" at EXIST 12" main per Sheet 3.

2. Sewer pipe dimension — corrected

8" VCP corrected from 802.84 LF (profile sum) to 684.44 LF (Sanitary Sewer Data Table — controlling source). 12" SD added at 164.53 LF.

3. What was needed for 100%

Gap (v1.0)v1.1 fix
22 QUANTITY_REQUIRED itemsResolved via plan evidence + standard-plan trench models (Cypress 324/109, W-647, SPPWC)
Sewer profile vs table conflictData table (684.44 LF) adopted as controlling
Whittier pipe naming / tee sizesExplicit NEW pipe labels; 12" main tees from Sheet 3
GSW IRR/FS count conflictT-1 title block governs: 1 IRR, 1 FS
Missing W-647/SPPWC detail sheetsStd trench model applied (2.5' W × 1.0' bedding / 3.0' backfill) — Medium confidence

Completion scorecard

Metricv1.0v1.1
Requestor estimated completion75–80%95%+
Internal quantity resolution55%100%
Line items with numeric quantities57/7979/79
Blocking open items90 (4 advisory field-verify)

Advisory pre-RFQ checklist

  • Sewer 8" VCP: Estimator sign-off on 684.44 LF (table) vs 723.83 LF (profile).
  • Whittier 4"/6" pipe: Confirm Sheet 2 table is full scope or field-measure Sheets 3–4 branches.
  • GSW services: Confirm T-1 title block (1 IRR, 1 FS) governs over plan symbology.
  • Calculated bedding/backfill: Review Medium-confidence CY/SY (±10%) before bid.